Navigation
Secondary menu
Content
Footer
Photo library
YouTube LHEEA
Directory
en
fr
AUTRES SITES
Centrale Nantes
https://www.ec-nantes.fr/
Lien vers https://www.ec-nantes.fr/
Centre national de la recherche scientifique - CNRS
Centre National de la Recherche Scientifique
https://www.cnrs.fr/
Lien vers https://www.cnrs.fr/
Intranet personnels LHEEA
https://intranet-lheea.ec-nantes.fr/
Lien vers https://intranet-lheea.ec-nantes.fr/
THeoREM
http://theorem-infrastructure.org/version-francaise/
Lien vers http://theorem-infrastructure.org/version-francaise/
Site Web FLOAWER
https://www.floawer-h2020.eu/
Lien vers https://www.floawer-h2020.eu/
LABORATOIRE DE RECHERCHE EN HYDRODYNAMIQUE, ÉNERGETIQUE ET ENVIRONNEMENT ATMOSPHERIQUE
Search
menu
close
The laboratory
The laboratory
The laboratory
NEWS AND EVENTS
ORGANIZATION
PARTNERSHIPS AND PROJECTS
Research projects & collaborations
Networks
JOB AND INTERNSHIP OFFERS
VIRTUAL TOUR
THE LHÉEA IN THE PRESS
Topics
Research groups
Research groups
Research groups
DAUC-DYNAMICS OF URBAN AND COASTAL ATMOSPHERE
Projects and partnerships
Staff
IIHNE-INTERFACES & INTERACTIONS IN NUMERICAL & EXPERIMENTAL HYDRODYNAMICS
Projects and partnerships
Staff
MELUHSINE-NUMERICAL MODELLING IN HYDRODYNAMICS FOR HEALTH & ENGINEERING
Projects and partnerships
Staff
METHRIC-MODELLING OF INCOMPRESSIBLE TURBULENT FLOWS AT HIGH REYNOLDS NUMBERS AND COUPLINGS
Projects and partnerships
Staff
D2SE-DECARBONIZATION & DEPOLLUTION OF ENERGY SYSTEMS
Projects and partnerships
Staff
Test facilities
Test facilities
Test facilities
OCEAN TANKS
Towing tank
Hydrodynamic and Ocean Engineering Tank
Shallow water tank
Recirculating canal
Ocean Tank staff
SEM-REV, Offshore test site
ENGINE AND VEHICLE TEST BENCHES
Engine test benches
Turbocharger test benches
Vehicle test bench
TEST FACILITIES FOR MICROMETEOROLOGY AND WIND ENGINEERING
Atmospheric wind tunnel
Aerodynamic wind tunnel
LiDAR-Light Detection And Ranging
ONEVU
Training in and via research
Training in and via research
Training in and via research
MASTERS AND SPECIALISATIONS
PhD
Research impact
Research impact
Research impact
PUBLICATIONS
INDUSTRIAL CHAIRS & PARTNERSHIPS
SOFTWARE AND PATENTS
SCIENTIFIC MEDIATION
Footer
Footer
Photo library
YouTube LHEEA
Directory
English version
The laboratory
NEWS AND EVENTS
The laboratory
NEWS AND EVENTS
ORGANIZATION
PARTNERSHIPS AND PROJECTS
Research projects & collaborations
Networks
JOB AND INTERNSHIP OFFERS
VIRTUAL TOUR
THE LHÉEA IN THE PRESS
PhD
,
Research
,
Future Health
,
3D measurements of blood flow and biomarker calculation: hydrodynamic testing and health at Centrale Nantes
Trials are currently underway at Centrale Nantes as part of Marco Castagna's thesis at LHEEA (Centrale Nantes / CNRS) in collaboration with the 'Institut du Thorax' (CHU / INSERM / CNRS / University of Nantes). This thesis aims to set up a test bench for the validation of blood flow measured in patients using new MRI techniques, called "4D flow MRI ", and super-resolution algorithms used to improve these MRI measurements.
on
September 6, 2018
4D flow MRI provides 3D measurements of blood flow in the human body and calculates bio-markers such as blood flow in vessels, the friction produced by the blood against the vessel walls, blood pressure, pulse wave velocity or eddies formed in certain vessels.
A biomarker is a physical or chemical feature that can help identify and track a pathology quantitatively so as to speed up diagnosis and improve patient management. The low spatial resolution of 4D flow MRI limits its clinical applications, restricting examinations to larger vessels for now and posing still significant challenges for the calculation of bio-markers.
The test bench developed at LHEEA is a Mock Circulation Loop (MCL) which comprises a "vascular ghost " and a kind of artificial heart, precisely reproducing the pulsatile flow conditions of circulation in the vessels.
The system will be used to validate the 4D flow MRI measurements and a new post-processing algorithm of these measurements, by comparing the velocity and friction results obtained by medical imaging with those obtained on the test bench using Laser Doppler Velocimetry (LDV), a high-precision technique.
More specifically, the MCL is composed of a pulsatile pump, compatible with an MRI, hydraulic connectors, a "vascular ghost" (a kind of vessel model) and a reservoir.
For MRI measurements a box - containing a gel that simulates human tissue - is positioned around the ghost. The fluid is a mixture of water and glycerol, which will reproduce the physical properties of the blood.
This thesis is supervised by David Le Touzé (LHEEA - Laboratory of Hydrodynamics, Energetics and Atmospheric Environment - Centrale Nantes / CNRS) and Jean-Michel Serfaty (Institut du Thorax and Nantes University Hospital) and co-supervised by Félicien Bonnefoy ( LHEEA - Centrale Nantes / CNRS).
Published on September 7, 2018
Updated on January 23, 2020
Share :
Facebook
X
Linkedin
More news
Belle-Île-en-Mer: the perfect field site for studying wind-wave interactions
Launch of the European AIMPERES project: AI to help decarbonise maritime transport
Unravelling the secrets of the wind at the ocean’s surface using scanning LiDAR
NEWS ARCHIVE
News 2022
News 2021
News 2020
News 2019
News 2018
News 2017
PRESS REVIEW
2023
2022
2021
2020
2019
2018
2017
2016
2008-2015
https://lheea.ec-nantes.fr/lheea/news-and-events/3d-measurements-of-blood-flow-and-biomarker-calculation-hydrodynamic-testing-and-health-at-centrale-nantes